myOSLchip dosimeter

myOSLchip dosimeter can be used for patient dosimetry, QC of radiation therapy treatment plans, research.

More details
myOSLchip

myOSLchip is a handheld OSL reader which can be used to read and *erase its compatible dosimeters called myOSLchip dosimeter. The myOSLchip is equipped with a touch display which allows autonomously measurements without PC connection.
Measurement data can be stored on a USB stick. Internal Data Matrix scanner identifies the individual number of the myOSLchip dosimeters.
The dosimeters can be used for patient dosimetry, QC of radiation therapy treatment plans, research,…
 
*erase function only for small dose application. High doses require thermal treatment.

More details
myOSLraser (reader+eraser)

myOSLraser is a small OSL reader for dose measurements in combination with our passive OSL dosimeter called myOSL.

State-of-art components, modern design and a user-friendly operating interface provide an excellent performance. The myOSLraser (reader+eraser) is designed to read the dose of each dosimeter without erasing the complete signal. Remaining dose signal can be used for a second readout. Additionally it is possible to erase the myOSL dosimeter directly after the dose measurement if a second readout is not required and to apply each myOSL dosimeter immediately for a next wearing period. myOSLraser will be available as a single read out OSL unit (one-by-one) or with an automatic feeder to process up to 200 myOSL dosimeter per loading.

More details
myOSL dosimeter

myOSL dosimeter is probably the smallest personal dosimeter based on OSL Technology.

The dosimeter contains 2 BeO detectors which provides accurate monitoring of X-rays/gamma rays of Hp(10) according to IEC-62387. The energy range will be from 16keV to several MeV.

Each dosimeter has its own number and can be pre-calibrated from production site. The myOSL dosimeter can be read in the manual or automatic OSL reader called myOSLraser (reader + eraser).

More details
TLDcube - manual TLD-Reader

TLDcube is a small, lightweight and portable TLD Reader for measuring, analyzing and evaluating of thermoluminescent materials. Modern design and software combine easy operation and excellent performance in this newly developed reader. The ceramic heater with defined nitrogen cooling in the rotating drawer accepts all standard TLD shapes.

TLDcube is available in two versions as TLDcube 400 with heating capability up to 400°C and as TLDcube 600 which provides heating capabilities up to 600°C.

The software includes calibration and QA features, data storage and export options as xml file or Excel file to meet all typical requirements.


Applications

  • Radiation protection
  • Environmental research
  • Medical dosimetry
  • Personnel Dosimetry
  • Experimental physics
  • Checking irradiated food

More details
RE-2000 - automatic TLD Reader

RE-2000 is an universal, low cost and high precision TLD reader for automatic or manual processing of dosimeter cards and single chips.

The reader can automatically process up to 200 dosimeter cards or 800 single TL-elements at one load depending on the model. The maximum processing speed is 160 single elements per hour. The photon counting method used over the whole measurement range provides an excellent signal to noise ratio for the measurement. Cooled PMT and built in self diagnostics guarantee high measurement stability and an error free operation.


RE-2000 is an universal, low cost and high precision TLD reader for automatic or manual processing of dosimeter cards and single chips.

The reader RE-2000 can automatically process up to 200 dosimeter cards or 800 single TL-elements at one load depending on the model. The maximum processing speed is 160 single elements per hour. The photon counting method used over the whole measurement range provides an excellent signal to noise ratio for the measurement. Cooled PMT and built in self diagnostics guarantee high measurement stability and an error free operation.


Features

  • Evaluation of whole body, extremity, beta, gamma, x-ray and neutron doses in single or mixed fields

  • Hole code or bar code identification of the dosimeter card

  • High measurement reproducibility with standard industrial N2 heating

  • Fully programmable pre-heat, measurement and anneal cycles

  • Automatic element-sensitivity correction, background subtraction and pre- and post calibration capability with WinTLDpro application software (see below).

  • Evaluation of whole body, extremity, beta, gamma, x-ray and neutron doses in single or mixed fields

  • Hole code or bar code identification of the dosimeter card

  • High measurement reproducibility with standard industrial N2 heating

  • Fully programmable pre-heat, measurement and anneal cycles

  • Automatic element-sensitivity correction, background subtraction and pre- and

  • post calibration capability with WinTLDpro application software (see below).


3 different models available:

TLD reader RE2000A: Automatically process up to 200 dosimeter cards or 800 single TL-elements at one load
TLD reader RE2000S: Automatically process up to 20 dosimeter cards or 80 single TL-elements at one load
TLD reader RE2000RT: Automatically process up to 20 dosimeter cards or 80 single TL-elements at one load including TL-Rods

More details